GNU bug report logs - #19895
24.4; battery.el does not support /sys/class/power_supply/BATX

Previous Next

Package: emacs;

Reported by: Greg Farough <gregf <at> riseup.net>

Date: Wed, 18 Feb 2015 16:54:01 UTC

Severity: normal

Found in version 24.4

Done: Stefan Kangas <stefan <at> marxist.se>

Bug is archived. No further changes may be made.

Full log


View this message in rfc822 format

From: help-debbugs <at> gnu.org (GNU bug Tracking System)
To: Greg Farough <gregf <at> riseup.net>
Subject: bug#19895: closed (Re: bug#19895: 24.4; battery.el does not
 support /sys/class/power_supply/BATX)
Date: Fri, 20 Sep 2019 23:46:01 +0000
[Message part 1 (text/plain, inline)]
Your bug report

#19895: 24.4; battery.el does not support /sys/class/power_supply/BATX

which was filed against the emacs package, has been closed.

The explanation is attached below, along with your original report.
If you require more details, please reply to 19895 <at> debbugs.gnu.org.

-- 
19895: http://debbugs.gnu.org/cgi/bugreport.cgi?bug=19895
GNU Bug Tracking System
Contact help-debbugs <at> gnu.org with problems
[Message part 2 (message/rfc822, inline)]
From: Stefan Kangas <stefan <at> marxist.se>
To: Greg Farough <gregf <at> riseup.net>
Cc: 19895-done <at> debbugs.gnu.org
Subject: Re: bug#19895: 24.4;
 battery.el does not support /sys/class/power_supply/BATX
Date: Sat, 21 Sep 2019 01:44:58 +0200
Greg Farough <gregf <at> riseup.net> writes:

> It seems that battery-linux-sysfs does not support certain laptop
> batteries which are not classified as BAT0, but by BATX instead. I had
> to add this to my .emacs to get display-battery-mode working properly:
>
> (eval-after-load 'battery
>   '(progn
>      (setq battery--linux-sysfs-regexp "[bB][aA][tT][xX]$")
>      (setq battery-status-function 'battery-linux-sysfs
>       battery-echo-area-format "Power %L, battery %B (%p%% charged, remaining time %t)"
>       battery-mode-line-format " [%p%%] ")))
> (display-battery-mode 1)

This has been fixed by the following commit on current master branch,
which makes 'M-x battery' list all batteries no matter what they're
named:

commit 6b38e34a11a85d50fa384b90ed21ea60d6d646d5
Author: Lars Ingebrigtsen <larsi <at> gnus.org>
Date:   Fri Aug 23 02:40:26 2019 +0200
    Have `M-x battery' list all batteries under GNU/Linux

I'm therefore closing this bug report.  If you could please verify that
the fix works for you and report back, that would be even better.

Best regards,
Stefan Kangas

[Message part 3 (message/rfc822, inline)]
From: Greg Farough <gregf <at> riseup.net>
To: bug-gnu-emacs <at> gnu.org
Subject: 24.4; battery.el does not support /sys/class/power_supply/BATX
Date: Wed, 18 Feb 2015 09:53:59 -0600
It seems that battery-linux-sysfs does not support certain laptop
batteries which are not classified as BAT0, but by BATX instead. I had
to add this to my .emacs to get display-battery-mode working properly:

(eval-after-load 'battery
  '(progn
     (setq battery--linux-sysfs-regexp "[bB][aA][tT][xX]$")
     (setq battery-status-function 'battery-linux-sysfs
      battery-echo-area-format "Power %L, battery %B (%p%% charged, remaining time %t)"
      battery-mode-line-format " [%p%%] ")))
(display-battery-mode 1)

Hope this helps, and thanks for all your hard work.
-g

-- 
Ξυνὸν δέ μοί ἐστιν, ὁππόθεν ἄρξωμαι· τόθι γὰρ πάλιν ἵξομαι αὖθις.